7-14. Adjusting the work clamp lift amount; 7-15. Adjusting the air pressure (pneumatic specifications); 7-14. Adjusting the work clamp lift amount - Page 107

Brother BAS-311G User Manual

Table of Contents

7. ADJUSTMENT
background image

7. ADJUSTMENT 

 

BAS-311G, BAS-326G 

100

7-14. Adjusting the work clamp lift amount 

<Solenoid specifications>

 

The operation panel settings can be used to adjust the height to within 15 

 25 mm. (Refer to "5-7. Setting the work clamp lift 

amount.") 
 

<Pneumatic specifications> 

The maximum lift amount for the work clamp is 30 mm above the top of the needle plate. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Turn on the air, and depress the work clamp switch (1) to raise the work clamp (2). 
2.  Loosen the two bolts (4) of the work clamp arm lever (3), and move the work clamp arm lever (3) up or down to adjust. 
 
 

7-15. Adjusting the air pressure (pneumatic specifications) 

Lift up the handle (2) of the regulator (1) and then turn it to 
adjust the air pressure to 0.5 MPa. 
After adjustment is complete, push the handle (2) 
downward to lock it. 
 
If water has collected in the bottle of the regulator (1), turn 
the drain cock (3) in the direction indicated by an arrow to 
drain the water. 
 

NOTE: 

Open the air cock (4) slowly. 

 
 
 
 
 
 
 
 
 
 
 
 
 

5019Q

5018Q 

5020Q

Max. 30mm

 

Detailed Information for Brother BAS-311G User Manual

Lists of information found in Brother BAS-311G User Manual - Page 107

  • 7. ADJUSTMENT BAS-311G, BAS-326G 100 7-14.
  • 7. Setting the work clamp lift amount.
  • 1. Turn on the air, and depress the work clamp switch (1) to raise the work clamp (2).
  • 2. Loosen the two bolts (4) of the work clamp arm lever (3), and move the work clamp arm lever (3) up or down to adjust.
  • 15. Adjusting the air pressure (pneumatic specifications) Lift up the handle (2) of the regulator (1) and then turn it to adjust the air pressure to 0.

Related Documents for Brother BAS-311G User Manual