2-4. List of memory switch settings; 2-4. List of memory switch settings ; 2. FUNCTION SETTINGS - Page 12

Brother BAS-311G User Manual

Table of Contents

7. ADJUSTMENT
background image

2. FUNCTION SETTINGS 

 

 

5

BAS-311G, BAS-326G

2-4. List of memory switch settings 

No. 

Setting 

range 

Setting items

 

Initial value

Work clamp lift timing after sewing is completed

 

OFF 

Lifts at the final stitch position.

 

001 

ON 

Lifts after moving to the home position.

 

ON 

Separate-type work clamp drop operation (pneumatic specifications)

 

Left and right work clamp drop at the same time. 

Work clamp drops in the order left 

 right. 

002 

Work clamp drops in the order right 

 left. 

Work clamp drop operation (solenoid specifications)

 

Analog dropping: Work clamp drops in direct proportion to the pedal depression 
amount, and sewing starts when the pedal is fully depressed

 

1st step drop: Work clamp drops when pedal is depressed to the 1st step, and 
sewing starts when pedal is depressed to the 2nd step 

003 

2nd step drop: Work clamp drops to intermediate height when the pedal is 
depressed to the 1st step, and work clamp drops and sewing starts when the 
pedal is depressed to the 2nd step. 

Sewing start speed

 

OFF 

The sewing speed for the first 1 

 5 stitches is set by memory switch numbers 151 

 155.

 

100 

ON 

1st stitch at 400 rpm, 2nd stitch at 400 rpm, 3rd stitch at 600 rpm, 4th stitch at 900 
rpm, 5th stitch at 2,000 rpm

 

OFF 

Single-stitch test feed

 

OFF 

Test feed starts when the foot switch (start switch) is depressed, and it continues 
automatically until the final stitch.

 

200 

ON 

Test feed is carried out one stitch at a time when the foot switch (start switch) is 
depressed (feed becomes continuous if the foot switch [start switch] is 
continuously depressed). 
In addition, when the TEST indicator is illuminated, test feeding will move forward 
one stitch at a time when the machine pulley is turned by hand.

 

OFF 

Production counter display

 

OFF 

Lower thread counter display

 

300 

ON 

Production counter display

 

OFF 

User programs

 

OFF Disabled

 

400 

ON 

User program mode is enabled.

 

OFF 

Cycle programs

 

OFF Disabled

 

401 

ON 

When sewing user programs, the set programs are sewn in numeric order.

 

OFF 

Maximum reduction ratio (mm display) (*1)

 

OFF 

Displayed as %.

 

402 

ON 

Displayed as mm.

 

OFF 

Split mode selection

 

Continuous split (split menu is disabled before split detection)

 

Continuous split (split menu is always enabled)

 

403 

2 Independent 

split

 

*1  The mm display may differ slightly from the actual sewing size. 