10-4. Removal of the fixed knife and the movable knife
Note:
Turn off the power switch.
â–
Removal of the fixed knife
1.
Remove flat-head screws
q
and then needle plate RR
w
and needle plate RL
e
.
2.
Remove clamping screws
r
and then tilt the machine head.
NOTE:
At this time, adjust the position of the machine head so that it is aligned with the notch in the bellows rail.
3.
Remove clamping bolt
t
and then bobbin case holder position bracket
y
.
4.
Remove flat-head screw
u
and then fixed knife
i
.
¡
When the fixed knife
i
becomes blunt, sharpen it as illustrated at right.
â–
Removal of the movable knife
w
y
q
r
1.
Remove flat-head screws
q
and then needle plate RR
w
.
2.
Remove clamping screw
e
and then presser foot assembly
r
.
3.
Turn the pulley and stop the needle bar at its highest position.
4.
Remove screw
t
and then needle
y
.
5.
Push thread trimming rod
t
in the arrowed direction and stop where flat-head screws
y
can be seen.
6.
Remove flat-head screws
y
and then movable knife
u
.
Note:
To reassemble, reverse the above procedures.
e
u
10. Adjustments
t
t
y
i
r
u
r
e
q
w
Belows rail
Notch
t
y