38
BAS-761
Error code
E – 500
E – 501
E – 502
E – 503
E – 504
E – 505
E – 510
E – 511
E – 512
E – 513
E – 520
E – 530
E – 535
E – 536
E – 540
E – 550
E – 560
E – 570
E – 580
E – 600
E – 700
E – 701
E – 710
E – 711
E – 720
E – 730
E – 740
E – 750
E – 780
E – 781
Reset
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Contents
Abnormal rise in 24 V power supply voltage (exceeds +20% of rating)
Abnormal drop in 24 V power supply voltage (exceeds -20% of rating)
Abnormal rise in 36 V power supply voltage (exceeds +20% of rating)
Abnormal drop in 36 V power supply voltage (exceeds -20% of rating)
Abnormal rise in primary voltage (exceeds +20% of rating)
Abnormal drop in primary voltage (exceeds -20% of rating)
Needle bar is not at its highest position at the start of positioning.
Needle bar is not at its highest position at the start of sewing.
Needle bar is not at its highest position during test feeding.
Needle bar is not at its highest position during programming.
Upper thread breakage error
Model and sewing program number do not match.
Retractable are for double (0 to 31) but data does not contain a double switching
command.
Model numbers are for single (32 to 63) but data does not contain a single
switching command.
Machine head synchronization sensor error or machine head motor error
Needle up stop error
Presser foot cylinder malfunction or sensor malfunction
Double sensor error
Needle racking cylinder malfunction or sensor malfunction
Machine started with no sewing data
Error occurred when reading from floppy disk
Error occurred when writing to floppy disk
No sewing data for number specified
Data writing carried out with no sewing data
No disk in floppy disk drive
Floppy disk is write-protected
Insufficient free space on floppy disk
Floppy disk cannot be formatted.
Sewing data exceeds sewing area
No end code in sewing data
12. Table of error code
12. Table of error code
¡
If an error occurs which cannot be reset, turn off the power momentarily and eliminate the cause of the problem.
¡
If an error occurs which can be reset, eliminate the cause of the problem and then press the RESET button.