Other ; 8. ELECTRICAL MECHANISM - Page 125

Brother BAS-311G User Manual

Table of Contents

7. ADJUSTMENT
background image

8. ELECTRICAL MECHANISM 

 

 

118

BAS-311G, BAS-326G

Other 

Trouble symptom 

Connector No. and position 

  DC fan motor does not operate. 

  [E740] is displayed. 

 
 
 
 
 
 
 
 
 
 

  Operation panel display is incorrect. 

  Power indicator does not illuminate. 

  Operation panel keys do not work. 

 
 
 
 
 
 
 
 
 
 
 
 

 Sewing machine does not start when foot switch is 

depressed. 

[Single pedal] 
Work clamp drops when depressed to the 1st step 
Home position is detected and sewing machine starts when 
depressed to the 2nd step 

[2 pedal] 
Work clamp drops when work clamp switch (left) is depressed 
Home position is detected and sewing machine starts when 
start switch (right) is depressed 

 
 
 
 
 
 
 
 
 
 
 

  After the power is turned on, [E055] is displayed. 

 
 
 
 
 
 
 
 
 
 

  After the power is turned on, [E452] is displayed. 

 
 
 
 
 
 
 
 
 
 

 

5245Q

5246Q

5247Q

5248Q

5249Q

Detailed Information for Brother BAS-311G User Manual

Lists of information found in Brother BAS-311G User Manual - Page 125

  • 8. ELECTRICAL MECHANISM 118 BAS-311G, BAS-326G Other Trouble symptom Connector No.
  • DC fan motor does not operate.
  • [E740] is displayed.
  • Operation panel display is incorrect.
  • Power indicator does not illuminate.
  • Operation panel keys do not work.
  • Sewing machine does not start when foot switch is depressed.
  • After the power is turned on, [E055] is displayed.
  • After the power is turned on, [E452] is displayed.