Problem    #7    When the foot switch is depressed, an error code is displayed. 

Cause

 

Inspection/Remedy/Adjustment

 

Replacement if a malfunction

 

1.  If the X feed moves slightly and 

then [E200] is displayed, there is 
a malfunction of the encoder. 

1) Check that connector P20 (X-ENC) is 

inserted into the main P.C. board. 

2)  Check the encoder input while referring to 

“2-8. Input checking method”. 

Pulse motor X assembly 

2. If the X feed moves and then 

[E200] is displayed, there is a 
malfunction of the X home 
position sensor. 

1) Check that connector P8 (SENSOR1) is 

inserted into the main P.C. board. 

2) Check the X home position sensor input 

while referring to “2-8. Input checking 
method”. 

3)  If a metallic object is brought close to the X 

home position sensor and the LED inside the 
sensor does not illuminate, there is a 
malfunction of the sensor. 

4) If it illuminates, the home position dog is 

incorrectly adjusted. 
Switch to home position adjustment mode, 
and adjust the position of the home position 
dog. (Refer to “7-20. Adjusting the home 
position”.) 

X home position sensor 

3.  If the feed mechanism does not 

move and [E200] is displayed, 
there is a malfunction of the 
pulse motor or cord. 

1) Disconnect connector P10 (XPM) from the 

PMD P.C. board, and measure the resistance 
between pins 1-2 and 3-4 at the cord-side 
connector. 
OK if 2

 

After measuring, insert P10. 

2)  If 1) is OK, there is a malfunction of the PMD 

P.C. board. 

 
 
 
 
 
 
 

Pulse motor assembly 
 
 
 
 
 
PMD P.C. board 

 
 

Problem    #8    When the foot switch is depressed, an error code is displayed. 

Cause

 

Inspection/Remedy/Adjustment

 

Replacement if a malfunction

 

1.  If the Y feed moves slightly and 

then [E210] is displayed, there is 
a malfunction of the encoder. 

1) Check that connector P4 (Y-ENC) is inserted 

into the main P.C. board. 

2)  Check the encoder input while referring to 

“2-8. Input checking method”. 

Pulse motor Y assembly 

2. If the Y feed moves and then 

[E210] is displayed, there is a 
malfunction of the Y home 
position sensor. 

1) Check that connector P8 (SENSOR1) is 

inserted into the main P.C. board. 

2) Check the Y home position sensor input 

while referring to “2-8. Input checking 
method”. 

3)  If a metallic object is brought close to the Y 

home position sensor and the LED inside the 
sensor does not illuminate, there is a 
malfunction of the sensor. 

4) If it illuminates, the home position dog is 

incorrectly adjusted. 
Switch to home position adjustment mode, 
and adjust the position of the home position 
dog. (Refer to “7-20. Adjusting the home 
position”.) 

Y home position sensor 

4885Q 

Detailed Information for Brother BAS-311G User Manual

Lists of information found in Brother BAS-311G User Manual - Page 135

  • 8. ELECTRICAL MECHANISM 128 BAS-311G, BAS-326G Problem #7 When the foot switch is depressed, an error code is displayed.
  • 1. If the X feed moves slightly and then [E200] is displayed, there is a malfunction of the encoder.
  • 8. Input checking method”.
  • 2. If the X feed moves and then [E200] is displayed, there is a malfunction of the X home position sensor.
  • 8. Input checking method”.
  • 3. If the feed mechanism does not move and [E200] is displayed, there is a malfunction of the pulse motor or cord.
  • 1. If the Y feed moves slightly and then [E210] is displayed, there is a malfunction of the encoder.
  • 8. Input checking method”.
  • 2. If the Y feed moves and then [E210] is displayed, there is a malfunction of the Y home position sensor.
  • 8. Input checking method”.