2. FUNCTION SETTINGS
18
BAS-311G, BAS-326G
PROGRAM No. display
Menu display
Check code
Name
Input status
Check item and checking method
[ 8]
[ UP]
[ on] / [ oFF]
Needle up signal
Turn the pulley by hand.
[ 9]
[ dn]
[ on] / [ oFF]
Needle drop signal
Turn the pulley by hand.
[ 10]
[voL]
[ 0]
−
[ 300]
Power supply voltage
Displayed as %
[ 11]
[PnL]
[*] / [ oFF]
Operation panel input check
While a key is being pressed, the name of the key will be
displayed.
*ON display
Key name
[rESt] RESET
key
[tESt] TEST
key
[tHrE] THREAD/CLAMP
key
[ tEn]
TENSION/WIND key
[SELE] SELECT
key
[UP-M]
key
[dn-M]
key
[ F1]
Function key F1
[ F2]
Function key F2
[ F3]
Function key F3
[ F4]
Function key F4
[ CF]
R/W key
[ 12]
[FtA]
[ 0]
−
[ 255]
Foot switch analog value (Single pedal specifications)
Depress the foot switch.
[ 13]
[CL1]
[ on] / [ oFF]
Work clamp 1st step (2 pedal specifications)
Depress the foot switch to the 1st step.
[ 14]
[CL2]
[ on] / [ oFF]
Work clamp 2nd step (2 pedal specifications)
Depress the foot switch to the 2nd step.
[ 15]
[Stt]
[ on] / [ oFF]
Start switch (2 pedal specifications)
Depress the foot switch to the 2nd step.
[ 16]
[EMC]
[
−
−
on]
[on
−
−
]
[
−
−
−
−
]
STOP switch
Press the STOP switch.
[ 17]
[HEd]
[ on] / [ oFF]
Machine head switch
Tilt back the machine head.
[ 18]
[EXE]
[ on] / [ oFF]
External input error detection (IN13)
[ 19]
[CAH]
[ on] / [ oFF]
Thread nipper hope position sensor (IN14) (*1)
Press the key to move the thread nipper in the home position
direction.
Press the key to move the thread nipper in the retract
direction.
[ 20]
[rEL]
[ on] / [ oFF]
Thread nipper retract sensor (IN15) (*1)
Press the key to move the thread nipper in the home position
direction.
Press the key to move the thread nipper in the retract
direction.
[ 21]
[in1]
[ on] / [ oFF]
Option input (IN1)
[ 22]
[in2]
[ on] / [ oFF]
Option input (IN2)
[ 23]
[in3]
[ on] / [ oFF]
Option input (IN3)
[ 24]
[in4]
[ on] / [ oFF]
Option input (IN4)
[ 25]
[in5]
[ on] / [ oFF]
Option input (IN5)
[ 26]
[rot]
[ on] / [ oFF]
Option input (IN11)
[ 27]
[Fib]
[ on] / [ oFF]
Fiber-type thread breakage detection [Option compatibility]
*1 Not used for the BAS-311G and BAS-326G.