2. FUNCTION SETTINGS - Page 19

Brother BAS-311G User Manual

Table of Contents

7. ADJUSTMENT
background image

2. FUNCTION SETTINGS 

 

 

12

BAS-311G, BAS-326G

 

No. 

Setting 

range 

Setting items 

Initial value

Thread breakage detector 

OFF Disabled 

554 

ON 

Fiber-type thread breakage detector used 

OFF 

Thread breakage detector detection sensitivity 

OFF 

5 stitches at sewing start, 3 stitches while sewing 

555 

ON 

10 stitches at sewing start, 3 stitches while sewing 

OFF 

Inner clamping device (Option output No. 13) 

0 Disabled 

Inner clamping device is used. 
(Retract operation is carried out at the sewing end to prevent interference with the 
needle.) 

Inner clamping device is used. (No retract operation at the sewing end.) 

556 

Inner clamping device operates for 1/4 of the sewing pattern and returns for the 
other 3/4. 
(No retract operation) 

External wiper device 

0 Disabled 

Solenoid-type wiper device is used. 

557 

Pneumatic-type wiper device is used. (Option output No. 2) 

External error monitoring input 

OFF Disabled 

558 

ON 

Enabled (P10, option input No. 13 [AIRSW]) 

OFF 

Operating indicator output 

OFF Disabled 

559 

ON 

Option output No. 9: Output ON while operating 
Option output No. 10: ON during lower thread conversion and during test mode 
Option output No. 11: ON when error is generated 

OFF 

Automatic ejector (Option output No. 3 output, option input No. 1 = right sensor, input No. 2 = left 
sensor) [Pneumatic specifications] 

0 Disabled 
1 Standard 

operation 

Sewing starts when cassette sensor is ON 

560 

Start switch is enabled even if cassette sensor is OFF. 

Timer from sensor detection to sewing start when automatic ejector automatic starting is set 
(memory switch No. 560 = 2) [Pneumatic specifications] 

561 

 999 

Time from after the cassette is chucked until automatic starting 

100 

Changes the digital tension setting value. 

OFF 

Tension number can be changed regardless of the sewing data. 

562 

ON 

Only tension No. 0 and the tension numbers detected in the sewing data can be 
changed. 

ON 

2-step tension is possible (When using spring-type main tension) 

OFF Disabled 

563 

ON 

2-step tension is used. 

OFF 

Increases maximum tension release force when using a spring-type main tension

 

Disabled (Tension release is open at the sewing end.) 

Increases the force (Tension release is closed at the sewing end. If tension release 
is open, it will be closed in approximately 5 minutes.) 

564 

Increases force to the maximum. (Tension release is closed at the sewing end. If 
tension release is open, it will be closed in approximately 1 minute.) 

Thread nipper device (*6) 

OFF Disabled 

565 

ON 

Thread nipper device installed (Memory switch No. 500 must also be set to ON or 
OFF.) 

OFF 

*6  Not used for the BAS-311G and BAS-326G.

 