2. FUNCTION SETTINGS
11
BAS-311G, BAS-326G
Data editing settings
No.
Setting
range
Setting items
Initial value
Sewing area limit in X direction [Units mm]
0
−
130
BAS-311G setting value
130
460
0
−
220
BAS-326G setting value
220
Sewing area limit in Y direction
461
0
−
100
[Units mm]
100
Enlargement/reduction reference point
0
Center of sewing frame
1
Sewing start point
462
2
Center of pattern
0
Enlargement/reduction for bar tacking
OFF
Bar tacking stitches (pitch approx. 1 mm or less) cannot be enlarged or reduced.
463
ON
Bar tacking stitches (pitch approx. 1 mm or less) are also enlarged or reduced.
OFF
Enlargement/reduction ratio in XY directions
OFF Disabled
464
ON
Enlargement/reduction ratio setting is the same for X and Y
(Disabled for user programs)
OFF
Storing parallel movement amount for sewing pattern
OFF
Initialized when program number or enlargement/reduction ratio is changed and
when power is turned off.
465
ON
Initialized when program number or enlargement/reduction ratio is changed but not
when power is turned off.
OFF
Reading sewing data from eternal media into internal memory
0
[Normal mode] Programs are copied one by one into internal memory.
1
[Overwrite mode] Sewing data is overwritten into the temporary buffer area.
If sewing data with the same program number already exists in internal memory, it
is deleted.
466
2
[Assignment mode] Sewing data is overwritten into the temporary buffer area.
If sewing data with the same program number already exists in internal memory, it
is not deleted, but only the data in the temporary buffer is used.
(If sewing data with the same program number already exists in internal memory
and the setting is changed to “0” or “1”, the data in the temporary buffer will be
cleared.)
0
Changing gear ratio correction method when reading from a 2DD floppy disk.
0
Automatic conversion as specified by sewing machine model.
(For the BAS-311G, data is read as BAS-311A data and then converted.)
1
BAS-311A data is read.
2
BAS-326A data is read.
467
3
BAS-341A/BAS-342A data is read.
0
Retract point switching at parallel movement point
OFF Disabled
468
ON
The position moved to by parallel movement is recorded as the retract point.
OFF
Device settings
No.
Setting
range
Setting items
Initial value
Needle cooler device
OFF Disabled
550
ON
Needle cooler device is used. (Option output No. 12)
OFF
Tension release setting at the sewing start
OFF Disabled
551
ON Enabled
OFF
Tension release timing during thread trimming [Units 8 degree steps]
552
-10
−
1
-10: Early
←
0: Standard
→
1: Late
0
Thread nipping timing (*5)
553
1
−
4
1: Early
←
2: Standard
→
4: Late
2
*5 Not used for the BAS-311G and BAS-326G.